KM KIT
Fluid Control Unit FCU 2000
Order Code: Structured by Type, Resolution, ISO Code format, Housing, Fluids, Options, Supply voltage, Supplementary details
HYDAC

Fluid Control Unit FCU 2000 Order Code: Structured by Type, Resolution, ISO Code format, Housing, Fluids, Options, Supply voltage, Supplementary details HYDAC

Universal equipment

Price on request

Request pricing and availability

Contact our specialists for details, compatibility and supply options.

Description

1. Function: Portable service unit for measurement of solid particle contamination in hydraulic and lubrication systems using infrared technology. 2. Measuring Range: Calibrated ISO 12/10/9 to 23/21/18. Measures up to class ISO 25/23/21. 3. Accuracy: Not explicitly stated in summary table. 4. Process Connection: INLET (pressure): Minimess test coupling type 1604/1620. OUTLET: male coupling DN 7. Optional suction port. 5. Output & Supply: Cleanliness classes per ISO/SAE/NAS. Integrated dot-matrix printer. RS232 interface (optional RS485). Supply: 24 VDC ± 25%. 6. Electrical Connection: Via power supply adapter (various regional versions). 7. Certifications: Protection class III, IP class IP40. 8. Housing: For portable use (model -1) or for 19" panel mounting (model -3). 9. Materials: For standard mineral oils or phosphate esters (HFD-R). 10. Options: With or without integral pump (model -4). Standard or BUS (RS485) interface. Various mains adapters for different countries.

Specifications

CategoryUniversal equipment
Product ID7010811710-1726
ManufacturerHYDAC
← Back to Catalog